Regulation guide

Introduction to the Water Regulations

Overview

PropertyValue
Fluid Categories1–5
Primary subjectWater fittings compliance and backflow prevention
Key requirementsBackflow protection, fitting quality, notification and water conservation

Arrow Valves has developed a series of Water Regulations tutorials to help designers and installers understand regulatory requirements and how they apply to different installations. Each tutorial focuses on a specific subject, bringing together relevant requirements and practical guidance.

The Water Supply (Water Fittings) Regulations 1999 came into force in England and Wales on 1 July 1999. Equivalent legislation applies in Scotland under the Water Supply (Water Fittings) (Scotland) Byelaws 2014 and in Northern Ireland under the Water Supply (Water Fittings) Regulations (Northern Ireland) 2009.

These requirements help protect the public water supply from contamination, waste and misuse.

Accessing the Water Regulations

Water Regs UK has retired the printed Water Regulations Guide and replaced it with free online guidance. This allows guidance to be reviewed and updated as requirements develop.

The relevant legislation, technical guidance and supporting publications can now be accessed through Water Regs UK:

The legislation includes Schedule 1, which defines the five Fluid Categories, and Schedule 2, which sets out specific requirements for water fittings and installations.

Key Requirements

Backflow Protection

Suitable backflow protection is required to prevent contamination of the water supply.

Reduced Pressure Zone (RPZ) valves, classified as Type BA devices, provide protection against risks up to Fluid Category 4, subject to the relevant installation requirements.

Fluid Category 5 represents the highest contamination risk and requires suitable protection, commonly provided through an appropriate air gap arrangement such as Type AA or Type AB.

Point-of-Use Protection

Schedule 2, paragraph 15 requires water systems to incorporate adequate protection against backflow from appliances, fittings and processes.

The protection must be suitable for the potential contamination risk. Many appliances already incorporate appropriate protection, such as an integral air gap, although this depends on the installation and its intended use.

Water Conservation

Schedule 2, paragraph 25 establishes requirements for WC and urinal flushing arrangements.

For most new WC installations, the maximum single flush volume is 6 litres. Dual-flush arrangements are permitted, subject to specified requirements.

Urinals can also be flushed using a pressure flushing valve and a Type DC pipe interrupter, provided the arrangement complies with the relevant installation and control requirements.

Risk Assessment

The required level of backflow protection depends on the potential contamination risk associated with an installation.

Hose union taps, washing machines and dishwashers are examples where the application and intended use influence the Fluid Category and protection requirements.

The local water undertaker determines the appropriate level of protection where necessary. Certain non-domestic applications are treated as Fluid Category 5 risks unless a different classification is accepted following assessment.

Approved Water Fittings

Regulation 4 requires water fittings to be of an appropriate quality and standard, and suitable for their intended use.

Independent certification schemes, including WRAS Approval, Kiwa UK Regulation 4 and NSF Reg 4, provide recognised evidence of product conformity.

However, product approval alone does not guarantee that a fitting is suitable for every application or that the complete installation complies with the Regulations.

Notification

Regulation 5 requires certain proposed plumbing work to be notified to the local water undertaker before work begins.

This includes the construction of new buildings, certain alterations to water systems and specified high-risk installations.

Approved Contractors are exempt from advance notification for some types of work, but these exemptions do not apply universally.

The relevant notification requirements and any conditions of consent should be confirmed with the local water undertaker before proceeding.

Downloads

Related Insights

Relevant field notes, audit learnings and specification articles.

Tools

Calculators and lookup tools that support this guide.

Applications

Where this regulation topic most commonly appears in real buildings and systems.

Application

Caravan Parks

Pitch supplies, wash blocks, site standpipes and seasonal water systems. Backflow from pitch hoses is the recurring failure.

Application

Leisure

Gyms, spas, pools, sports facilities and public changing areas. Showers, hose points and chemical dosing.

Application

Industrial

Process water, dosing, washdown, plant rooms and production services. Category 4 and 5 predominate.

Application

Hospitality

Hotels, restaurants, kitchens, laundries and guest washroom facilities. High-turnover fittings and hose-union points.

Application

Healthcare

Hospitals, clinics, care settings and specialist clinical water systems. HTM 04-01 and Category 5 washdown dominate specification.

Application

Residential

Domestic dwellings, flats, landlord stock and mixed-use residential blocks. Typical risks are hose-union taps, filling loops and garden irrigation.

Products

Product families commonly specified against this guide.

Quick Links

Downloads

3 documents

Related insights

4 articles

Related tools

1 tool

Applications

3 sectors

Need help specifying?

Our technicians can walk the current risk, the required device, and the assembly that satisfies AIM.

Regulation guide

Insights on

Introduction to the Water Regulations

Tools & calculators

Calculate, look up, decide