The Water Regulations establish requirements for the installation of stopvalves, servicing valves and drain taps within water supply systems.
Unlike the previous Water Byelaws, which specified particular valve standards and designs, the Water Regulations take a more performance-based approach.
This allows different valve designs to be used, provided they meet the applicable requirements and are suitable for their intended purpose.
Spherical valves, commonly known as ball valves, can therefore be used for many isolation applications.
Stopvalves
A stopvalve is used to shut off the water supply to premises or a particular part of a water system.
Schedule 2, paragraph 10 establishes two principal requirements.
Separate premises
Every supply or distributing pipe providing water to separate premises must incorporate a conveniently located stopvalve.
The valve must allow the water supply to those premises to be isolated without interrupting supplies to other premises.
Shared water supplies
Where a supply or distributing pipe serves two or more premises, a stopvalve must be provided to which each occupier has access.
This is particularly relevant to buildings containing several separately occupied units, including flats, commercial premises and other shared developments.
The external stopvalve is normally provided and maintained by the water undertaker. An accessible internal stopvalve allows the occupier to isolate their own water supply.
Water Regs UK recommends that stopvalves are clearly identified and positioned where they can be operated without difficulty.
Spherical Valves as Stopvalves
Traditional stopvalves commonly used a screw-down mechanism with a rubber washer.
Under the Water Regulations, suitable spherical (ball) valves can also be used as stopvalves.
These valves provide rapid, quarter-turn operation and are available in a wide range of sizes and connection types.
However, the valve must be appropriate for its intended use, including the operating pressure, temperature, materials and installation environment.
A ball valve used as a stopvalve must also provide suitable means of operation and isolation.
Water Regs UK advises designers to consider ease of operation and the effects of rapid valve closure, which can cause pressure surges within the pipework.
Valve Quality and Suitability
Regulation 4 requires water fittings to be of an appropriate quality and standard and suitable for their intended purpose.
Compliance can be demonstrated through recognised standards, testing or suitable third-party certification.
The fact that a valve is approved for contact with wholesome water does not automatically mean it is suitable for every installation.
Its operating characteristics and the manufacturer’s instructions must also be considered.
How Spherical Valves Work
Spherical valves use a rotating ball containing a passage through its centre.
When the passage aligns with the pipework, water flows through the valve.
Rotating the ball through 90 degrees closes the passage and isolates the supply.
The construction typically includes:
- A rotating ball.
- Main seals, commonly manufactured from PTFE.
- A spindle or stem connecting the ball to the operating handle.
- A spindle seal preventing leakage around the operating mechanism.
- A valve body containing the assembly.
The ball is sealed against its seats by the pressure differential across the valve.
The design and quality of these sealing components influence the valve’s reliability, operating performance and service life.
Main Valve Seals
Many spherical valves incorporate two PTFE seats, one on either side of the ball.
Some economy designs incorporate only one principal sealing seat and are therefore intended for use in a particular flow direction.
Where a directional valve is used, the manufacturer’s flow-direction marking must be followed.
Some designs use specially shaped seals or PTFE seats supported by O-rings to improve sealing performance.
These features can be particularly useful in three-port valve arrangements.
Spindle Seals
The spindle seal prevents water escaping around the operating stem.
Some valves use an elastomeric O-ring, while others incorporate a PTFE seal and adjustable gland nut.
An adjustable gland can allow minor spindle leakage to be corrected without removing the valve from the pipework.
Certain designs also allow the spindle seal to be replaced while the valve remains installed.
The choice of sealing material depends on the operating temperature and the fluid being controlled.
PTFE offers good resistance to a wide range of fluids and temperatures. Elastomeric seals have different limitations, and their suitability must be checked against the manufacturer’s specification.
The original Arrow tutorial identifies EPDM O-rings as generally limited to approximately 85°C and unsuitable for oils. These are material-selection considerations rather than universal limits for every EPDM formulation.
Benefits and Limitations of Spherical Valves
Spherical valves offer several advantages over traditional screw-down valves.
| Benefits | Limitations |
|---|---|
| Full-bore designs can provide very low head loss | Water trapped inside the ball cavity can cause damage if it freezes |
| Quarter-turn operation allows rapid isolation | Rapid closure can contribute to water hammer |
| Suitable designs are available for water and other fluids | Seal and material compatibility must be confirmed |
| PTFE sealing components can offer a long service life | Main seats are not generally replaceable on many designs |
| Compact construction and a wide choice of sizes | Some internal arrangements can be bypassed when a valve is partly open |
| Modular designs can incorporate additional functions | Maintenance and replacement arrangements depend on the valve design |
These advantages make spherical valves suitable for many stopvalve and servicing valve applications.
However, a valve should not be selected solely because it is full-bore or inexpensive.
Operating conditions, maintenance access and the required isolation performance must also be considered.
Modular Spherical Valves
A development of the conventional ball valve allows additional components to be installed inside the ball itself.
A side access port provides access to the component without removing the valve from the pipework.
With the valve correctly closed, the upstream and downstream connections can be isolated from the central access point, allowing the component to be serviced or replaced.
Arrow Valves uses this arrangement in its Automatic Flow Limiting (AFL) Servicing Valve.
Automatic Flow Limiting Valves
The AFL can incorporate one of eight colour-coded flow-limiting cartridges.
These cartridges regulate the maximum water flow to the selected rate.
The valve can also incorporate a strainer, allowing isolation, flow control and filtration to be provided within one assembly.
The cartridges can be installed or changed through the side port without disconnecting the pipework or draining the system, following the prescribed servicing procedure.
This modular arrangement is useful where water consumption must be controlled at individual outlets.
Partially Open Ball Valves
A limitation of some modular spherical valves is that water can pass around the outside of the ball when the valve is partially open.
This can allow flow to bypass a component installed within the ball.
The distinction is particularly important where the central component is a non-return valve.
For example, Arrow’s Ballstop arrangement must not be treated as an approved Single Check Valve for Water Regulations backflow protection.
A non-return function suitable for pump protection does not automatically provide recognised backflow protection for a wholesome water supply.
Where protection against contamination is required, an appropriate backflow prevention device must be selected for the assessed Fluid Category.
Spherical Valves and Frost Protection
Spherical valves can be vulnerable to freezing because water can remain trapped inside the ball or between the ball and valve body.
When water freezes, it expands and can exert considerable pressure on the surrounding components.
This can cause the valve body to fracture even when the pipework has otherwise been drained.
The same problem can occur in spherical hose union taps installed outdoors.
Draining Ball Valves
Where a spherical valve is used in a system that needs to be drained for frost protection, its position after draining is important.
The original Arrow tutorial recommends leaving a suitable valve partially open, approximately 45 degrees, so that water trapped within the ball and surrounding cavity can escape.
This should only be done where the valve design and the system’s operating requirements allow it.
Valves exposed to freezing conditions should be selected and installed to minimise the risk of retained water.
Where appropriate, a different drain tap design or additional frost protection should be considered.
Arrow Valves’ SPED Standpipe uses a conventional hose union bib tap as part of its frost-protection arrangement.
Operating Handles
Spherical valves are normally operated using a lever or other suitable mechanism.
Older Water Byelaws specified certain operating arrangements for servicing valves, including screwdriver-operated slots in particular applications.
The current Water Regulations allow other suitable operating mechanisms.
Lever-operated valves can therefore be used where appropriate.
Some designs incorporate locking facilities that allow the valve to be secured in the fully open or fully closed position.
Depending on the model, this can be achieved using a removable handle, key or padlock.
Lockable arrangements are useful where unauthorised operation could interrupt essential services or cause water wastage.
Servicing Valves
A servicing valve is used to isolate an individual water fitting or a particular part of a system for maintenance or replacement.
Unlike a stopvalve serving entire premises or a wider zone, a servicing valve is intended to allow work to be carried out without unnecessarily interrupting other water supplies.
Schedule 2, paragraph 11 requires water systems to incorporate an adequate number of servicing valves and drain taps.
The purpose is to minimise water loss when fittings are maintained or replaced.
Servicing valves should be installed as close as practicable to the fittings or parts of the system they control.
Examples include:
- WC and urinal flushing cisterns.
- Storage cistern inlet and outlet connections.
- Washbasin and sink supplies.
- Water-using appliances.
- Other fittings requiring periodic maintenance.
Where appropriate, valves should be identified to show which parts of the installation they isolate.
Servicing Valves for WC Cisterns
WC flushing cisterns commonly incorporate internal overflow arrangements.
Where an inlet valve fails to close correctly, water can pass into the WC pan through the internal overflow without an obvious external warning.
Debris entering the float valve can contribute to this problem.
A suitable strainer upstream of the inlet valve can help protect its operation.
Arrow Valves’ AFL Servicing Valve can incorporate a serviceable 180 µm strainer.
This allows the strainer to be accessed for cleaning while also providing isolation of the cistern supply.
The selected arrangement must satisfy the applicable requirements for the cistern and its inlet valve.
Drain Taps
Drain taps allow water to be removed from pipework for maintenance, repairs or periods when the system is not in use.
Schedule 2, paragraph 11 requires water systems to be capable of being drained down.
An adequate number of drain taps must be provided so that unnecessary quantities of water are not lost when fittings are maintained or replaced.
Drain taps should be:
- Positioned to allow the relevant pipework to be drained.
- Readily accessible for operation and maintenance.
- Protected against freezing where necessary.
- Installed so they are not submerged or exposed to contamination.
Water Regs UK also advises that drain taps should not be buried under soil or located where they are likely to become submerged.
Selecting Drain Taps
Traditional screw-down drain taps and suitable spherical drain taps are both available.
The original Arrow tutorial refers to BS 2879 screw-down drain taps and the use of approved spherical types in frost-free locations.
The risk of trapped water must be considered when specifying spherical drain taps in exposed locations.
As with servicing valves, the aim is to provide effective isolation and draining while minimising water wastage.
Secondary Backflow Protection
Stopvalves and servicing valves isolate water supplies, but they do not themselves provide protection against contamination by backflow.
In buildings with shared supply pipework, additional backflow protection can be required to prevent potentially contaminated water passing between separately occupied premises.
This is commonly described as secondary, zone or whole-site backflow protection.
Separately Occupied Premises
Examples include:
- Blocks of flats.
- Offices with separate occupiers.
- Industrial units.
- Schools and other large buildings.
- Commercial premises supplied from common distribution pipework.
Where several premises share a supply or distributing pipe, the water undertaker can require additional protection to prevent contamination spreading between different parts of the system.
The appropriate protection depends on the assessed contamination risk.
For suitable applications where the risk does not exceed Fluid Category 3, a Double Check Valve can provide the required level of protection.
Higher risks require correspondingly suitable protection.
Floor-Level and Branch Protection
The original Arrow tutorial refers to Water Industry guidance recommending secondary protection on branches serving individual floors or separately occupied units.
For example, a Double Check Valve can be installed immediately downstream of the stopvalve on a floor-level branch serving fittings assessed as Fluid Category 3.
This arrangement can help protect other floors or branches connected to the same distribution system.
However, the need for floor-level, zone or whole-site protection and the appropriate device are determined by the installation’s risks and the local water undertaker’s requirements.
It should not be assumed that the same Double Check Valve arrangement is sufficient for every building.
Point-of-Use Protection Still Applies
Providing secondary protection does not remove the requirement for appropriate backflow protection at individual appliances, fittings and processes.
Schedule 2, paragraph 15 requires adequate protection against backflow.
Whole-site or zone protection provides an additional safeguard, but it cannot automatically replace point-of-use protection.
Arrow Valves Branch Valve Assemblies
Arrow Valves developed its Branch Valve (BRV) range to combine isolation and backflow prevention functions within a compact assembly.
The standard arrangement incorporates:
- A full-bore servicing or stopvalve.
- A low head-loss Double Check Valve.
- Flat-faced union connections.
The original tutorial also illustrates an assembly incorporating a drain tap.
Flat-Faced Connections
Flat-faced connectors allow the assembly to be fitted using suitable unions, including solder union connections.
EPDM sealing washers provide the seal between the flat-faced connections.
This arrangement enables the valve assembly to be installed or removed without requiring unnecessary movement of the adjoining pipework.
The connections also allow components such as operating handles and drain taps to be aligned during installation.
Low Head-Loss Backflow Protection
The Branch Valve incorporates a low head-loss Double Check Valve, based on Arrow’s ED132 design.
This provides Fluid Category 3 backflow protection while minimising the loss of available supply pressure.
Low head loss is particularly relevant where several protective devices are installed along a distribution system.
Modular Options
The Branch Valve range can incorporate additional functions depending on the installation.
The original Arrow tutorial identifies the following arrangements:
| Model | Additional function |
|---|---|
| BRV | Branch Valve with isolation and Double Check Valve protection |
| BRFB | Additional strainer, based on the Filterball design |
| BRPRV | Pressure reducing valve |
| BRM | Secondary water meter |
| BRPRMV | Combined pressure reducing valve and water meter |
The modular arrangement allows isolation, backflow protection, pressure control and metering functions to be combined where required.
These assemblies can be installed horizontally or vertically, subject to the selected components and manufacturer’s installation requirements.
Summary
When selecting and installing isolating valves:
- Provide accessible stopvalves so supplies to separate premises can be isolated without interrupting other premises.
- Select suitable spherical valves where their construction, materials, operating characteristics and conditions of use are appropriate.
- Provide adequate servicing valves and drain taps to allow maintenance without unnecessary water wastage.
- Consider frost damage where spherical valves or hose union taps can retain water within their bodies.
- Assess secondary backflow protection on shared supplies, floor branches and separately occupied premises in accordance with the water undertaker’s requirements.
- Maintain point-of-use backflow protection even where zone or whole-site protection is provided.
- Consider modular branch valve assemblies where isolation, backflow prevention, filtration, pressure control or metering functions are required.